What are the delay times for DSC 1616?
David Jones
Published Feb 21, 2026
What are the delay times for DSC 1616?
The system has 3 timers that you can set: entry delay 1, entry delay 2, and exit delay. The entry delays need to be between 30 seconds and 255 seconds. The exit delay must be between 45 seconds and 255 seconds. Press *8-installer code to go into programming. Enter 005. The system will then want a two digit partition number.
How does the alarm work on a pc1616?
A sensor in alarm will be indicated by the corresponding zone lights flashing on a LED keypad or by written mes- sages on the LCD keypad. Additional features of the PC1616/PC1832/PC1864 Security System are an Automatic Inhibit (Swinger Shutdown) for Alarm, Tamper and Trouble signals after 3 occurrences in a given set period.
How do I set the exit delay on DSC?
The system has 3 timers that you can set: entry delay 1, entry delay 2, and exit delay. The entry delays need to be between 30 seconds and 255 seconds. The exit delay must be between 45 seconds and 255 seconds. Press *8-installer code to go into programming. Enter 005. The system will then want a two digit partition number. Enter 01.
Where is the socket on a pc1616?
For North America the equipment is a direct plug-in connection; the socket outlet shall be installed near the PC1616/1832/1864 and shall be easily accessible. The plug of the direct plug-in transformer serves as the disconnect device.
The system has 3 timers that you can set: entry delay 1, entry delay 2, and exit delay. The entry delays need to be between 30 seconds and 255 seconds. The exit delay must be between 45 seconds and 255 seconds. Press *8-installer code to go into programming. Enter 005. The system will then want a two digit partition number.
Where can I use a pc1616 alarm system?
WARNING: This equipment, PC1616/1832/1864 Alarm System shall be installed and used within an environment that provides the pollution degree max 2 and over-voltages category II non-hazardous locations, indoor only.
The system has 3 timers that you can set: entry delay 1, entry delay 2, and exit delay. The entry delays need to be between 30 seconds and 255 seconds. The exit delay must be between 45 seconds and 255 seconds. Press *8-installer code to go into programming. Enter 005. The system will then want a two digit partition number. Enter 01.
For North America the equipment is a direct plug-in connection; the socket outlet shall be installed near the PC1616/1832/1864 and shall be easily accessible. The plug of the direct plug-in transformer serves as the disconnect device.